top of page
工業機械

INDUSTRIAL ELECTRIC

These components aren’t just sourced  - they’re battle-tested.

GEOCON filters out the unreliable, the unresponsive, and the untrustworthy so you don’t have to. You get dependable industrial electrics with minimal effort and maximum market return.

Finding Solution in Every Turn


It is mainly for industrial electrical products such as low-voltage power distribution and industrial control appliances, intelligent instruments, power appliances, frequency converters, high-voltage appliances, and building appliances, providing high-quality low-voltage electrical products and solutions for industries such as electricity, communications, new energy, industrial and civil construction, metallurgy, petrochemicals, and machinery manufacturing.

未命名.png

SB1N-63 Air Circuit Breaker

AC 50/60Hz

Rated voltage 230V/400V

It is used for overload and short-circuit protection of power line facilities and electrical equipment in household and similar places with rated current up to 63A, and can also be used for infrequent on-off operations. Especially suitable for industrial and commercial lighting distribution systems.

Main technical parameters of the product

Comply with standards

Product Certification

Number of poles

Rated frequency (Hz)

Frame grade current (A) Inm

Rated current (A)  Ie

Rated voltage

Rated insulation voltage (A)  Ui

Rated impulse withstand voltage (kV)  Uimp

Rated operating short-circuit breaking capacity (kA)  Ics

Rated short-circuit breaking capacity (kA)  Icn

Instantaneous tripping characteristics

Tripping mode

Pollution degree

Electrical and mechanical accessories

Electrical life

Mechanical life

Protection level

Operating ambient temperature

Installation altitude

Terminal Blocks

Maximum wiring capacity (mm²)

Maximum torque (Nm)

Installation Category

Installation

Wiring Direction

GB/T10963.1 IEC/EN60898-1

CQC, CE, TUV, CB, self-declaration

1P, 1P+N, 2P, 3P, 3P+N, 4P (N pole can be opened and closed)

63

50/60

1、2、3、4、5、6、10、16、20、25、32、40、50、63

AC230/400(1P) AC230(1P+N) AC400(2P、3P、3P+N、4P)

690

4

6

6

B(3In - 5In) C(5In - 10In) D(10In - 14In)

Thermal magnetic trip

2

MX: Shunt release
OF: Auxiliary contact
SD: Alarm contact
MX+OF: Shunt + auxiliary release
MV: Overvoltage release
MN: Undervoltage release
MV+MN: Overvoltage and undervoltage release
MNS: Loss of pressure release

10000

20000

IP20

-35℃ to +70℃

No more than 2000m

Screw crimping

25

2.5

Class II, III

TH35-7.5 standard guide rail

Both top and down input/output supported

Operating Characteristics of the Overcurrent Tripping Device (See The Table)

Protection Characteristic Curves of the Circuit Breaker

Type B Protection Characteristic Curve

Type C Protection Characteristic Curve

Type D Protection Characteristic Curve

未命名.png

Wiring

Applicable for connection with wires of 25 mm² or smaller (see the below Table).
Wiring method: screw-type terminal connection, with a tightening torque of 2.5 N·m.

未命名.png

Installation Dimensions

未命名.png

GEOCON GLOBAL CO., LTD.

TEL +886-5-2776109

FAX +886-5-2776209

2F., No 25-1, Minle St., East Dist., Chiayi City 60050, Taiwan R.O.C.

Copyright © 2026 GEOCON GLOBAL All rights reserved

bottom of page